Features                        

-Application:0.5~150KGS animals

-Turbine driven:tidal volume 5-1500ml, ±4ml or 10% whichever is large;oxygen saving and provide small animals anesthesia

-Integrated design:built-in bellows and breathing circuit and space saving

-Large touch screen:10 inch TFT, capacitive touch screen;simultaneous display of multiple waveforms and 6 parameters; intuitive and convenient operation

-Two AC power outputs,facilitate collaboration with other devices

-Gas monitoring:optional configuration for CO2 and anesthesia gas monitoring;safer anesthesia

 

Technical Specifications

PARAMETER

SPECIFICATION

Display

Display screen

10.1 inch touch screen, 1280X800 resolution

Input voltage

100V-240V, 50Hz/60Hz

Battery type

Lithium Ion Battery , 14.8V, 5000mAh

Minimum battery power supply time

120 minutes

Output

2 AC outputs, 100V-240V/1.8A~0.9A, 50Hz/60Hz

Ventilator

Driving method

Turbine

Ventilation modes

VS, VPS,VCV, PCV, SIMV

Parameter

Setting Range

Tidal volume (Vt)

5ml-1500ml

Inspiratory pressure (Pinsp)

5cmH2O-50cmH2O

Support pressure (Psuppl)

3cmH2O-50cmH2O

Positive end expiratory pressure (PEEP)

OFF, 3cmH2O-30cmH2O

Respiratory Rate (RR)

2bpm-60bpm

Min.respiratory rate (Min RR)

2bpm-60bpm

Inspiratory to expiratory ratio (I:E)

4:1-1:8

Inspiratory time (Tinsp)

0.2S-10.0S

Trigger pressure (P-Trig)

-20cmH2O~-0.2cmH2O

Trigger flow rate(F-Trig) BTPS condition

0.2L/min-15L/min

Parameter name

Monitoring scope

Tidal volume (Vt)

0ml-3000ml

Minute ventilation volume (MV)

0L/min-100L/min

Peak Airway Pressure (PEAK)

-20cmH2O~100cmH2O

Positive end expiratory pressure (PEEP)

0cmH2O-70cmH2O

Respiratory Rate (RR)

0bpm-120bpm

Inspiratory to expiratory ratio (I:E)

20:1-1:20

Circuit System

Source gas

Compressed oxygen/compressed air/oxygen

Gas pressure range

280-600kpa/40-87psi

Port type

NIST/DISS

Gas pressure gauge

0-1Mpa/0-140psi

Air source safety valve

Built in

Flow meter adjustment

0-4L/min

Vaporizer tank base

Single tank position, Selectatec

Respiratory System

Manual breathing bag

Coaxial 22mm (OD) / 15mm (ID)

Inspiratory Valve Port

Coaxial 22mm (OD) / 15mm (ID)

Expiratory Valve Port

Coaxial 22mm (OD) / 15mm (ID)

ACGO Port

Coaxial 22mm (OD) / 15mm (ID)

AGSS Port

30mm outer conical joint

Airway pressure

-20cmH2O~100cmH2O

APL valve

Adjustment range: 0 ~ 70cmh2o, with one key closing

CO2 Absorber Canister

Volume 1400ml

Packing Information

Dimension

Height 1500mm X Width 487mm X Length 537mm

Weight

=28kg (include stand, vaporizer and other accessories)

Maximum Load on Top

10kg

Environmental Specifications

Environmental

Temperature: 10~40 ; Relativ e humidity 15%~95%

Storage environment

Temperature:-20~60 ; Relativ e humidity : 10%~95%

Options

Ventilation modes

PCV, SIMV

Source gas

Dual gas source/oxygen concentrator

Trolley & extension

Trolley , oxygen concentrator platform, Single/Dual E

Monitoring modules

Mainstream/sidestream CO2 monitoring

Disposable accessories

Large, medium and small breathing circuits, Bain breathing circuit, anesthesia masks, Laryngoscope, anesthesia gas filter canister, cylinder regulator, tracheal intubation

 

Standard Configuration

Main unit, anesthesia ventilator, one anesthesia vaporizer, one mobile trolley, one set oxygen hose, one set disposable breathing hose, one set waste gas hose, one set breathing bag (with 4 size), one set power cord, one set winder accessories

 